Lower space requirements up to approx.
Medium voltage switchgear grounding.
Bond the equipment grounding conductors to the switchgear ground bus to all manhole grounding provisions and hardware to the cable shield grounding provisions of medium voltage cable splices and terminations and to.
When terminating medium voltage cables in to a switchgear with zero sequence ct core balance ct the cable shield needs to be routed as discussed below for ground fault relay to operate properly.
Hvl cc medium volta ge metal enclosed switchgear general and application information general square d brand medium voltage metal enclosed switchgear functions as a prime component of medium voltage electrical power distribution systems providing necessary switching and overcurrent protection for the medium voltage feeders.
Medium voltage switches for use on 1 52kv indoor systems are predominantly used for isolation and earthing.
70 savings with 30 kv compared to air insulated switchgear.
The following should be noted.
Gas insulated switchgear should be used for the medium voltage consumer substation.
Modern grounding switches allow personnel to perform maintenance grounding with switchgear completely enclosed.
With a draw out safety device that can be inserted into a circuit breaker cubicle in the same manner as the vr series the ground and test devices are available as a single.
The advantages of gas insulated switchgear are.
6 1 medium voltage metal enclosed switches introduction outdoor medium voltage switch contents description introduction an eaton green solution introduction product selection guide product offering chart metal enclosed 1 notes 1 additional products not shown include medium voltage transfer high resistance ground and low profile switchgear.
Smaller transportation size and consequently easier shipping.
New approaches for maintenance grounding in medium voltage switchgear schneider electric white paper revision 0 page 5 a third practice used is main grounding.
Although the majority of these switches are air insulated gas insulated sf6 combination switches are available which are designed for load and fault current switching.
In this method the ground is applied to the line side of the main switch or circuit breaker in switchgear figure 3a.
Conductor in each duct containing medium voltage conductors sized per nec except that minimum size shall be no.
Eaton s medium voltage ground and test devices are used to apply temporary grounding to the phase conductors of switchgear during maintenance and testing of the equipment.