What is not as well known is its other equally important function.
Medium voltage cable shield grounding.
Systems in these voltage ranges are commonly referred to as medium voltage systems.
Medium voltage cable shielding and grounding abstract.
The most overlooked if not a well understood factor is the type of power cable that s required for the application and when to ground the cable s neutral or tape shield.
Grounding methods and requirements for systems operating at more than 1 000 volts v such as 5 and 15 kilovolt kv systems differ slightly from those for systems of 1 000v or less.
Verification of shield performance under ground fault conditions will prevent systemwide cable damage as we all know the metallic shielding in a medium voltage mv cable provides the necessary uniform electric field within the cable s insulation.
Shield losses shield grounding and shield terminations are also discussed.
Single conductor.
If an unshielded insulated cable is in contact with earth or a grounded object the electrostatic field around the conductor will be concentrated at the contact point resulting in corona discharge.
Medium and high voltage power cables in circuits over 2000 volts usually have a shield layer of copper or aluminum tape or conducting polymer.
Tape shielded drain wire shielded general cable unishield concentric neutral cn jacketed concentric neutral jcn beyond cable shield types two common configurations are used.
This article discusses the medium voltage mv or high voltage hv cable shield grounding or termination methods.
It is noted that in essence the conductor shield is an electrical extension of.
Why do high voltage cables have shields.
Medium high voltage cable types of the nearly limitless variety of cables in use today five of the most common are.
With its extensive technical and engineering expertise and a state of the art compound facility general cable is committed to using materials with the best overall properties to create the most comprehensive line of industrial power cables to meet your design requirements.
The nec provides several rules related to the grounding of these systems and associated equipment.
General cable is recognized as a world class leader in the development and design of medium voltage industrial cables.
Shielding of electric power cable results in symmetric electric field distribution within the cable insulation and prevents stress damage.
From an engineering standpoint there are several factors one needs to consider before installing the cable.